  • 1 October 2026 by
    New OptiFlex Gen5 driver drv_gen5_108-08-30000 has been posted
    PILOGIC, MARCHAND Sylvain

    v108-08-30000

    Models Supported

    • G5RE, G5CE, OFHI, OFHI-A, OFISO-E2, OFCSR-E2, OFINT-E2, OFRTR-E2-S2.

    Issues fixed in .update files :

    • Reading a device object list with more than ~2,900 entries falls back to reading each object in the list individually, causing pending operations to timeout and never complete
    • Port S1 packet counts are not updated on hardware without rotary switches
    • Controller not responding to non-segmented confirmed requests with broadcast MAC address on local data link
    • Digital wire trend in equipment causes control program to halt
    • Net LED and Warning Message History in modstat do not display correctly when Ethernet is disconnected on B/SC homed controller
    • PCAP files show milliseconds as microseconds
    • UDMI payloads have non-string values in quotes
    • ARC156 glitch filter set too wide, sometimes leading to discarded bits from distant controllers on longer ARCNETs
    • Historian enabled trends with max samples and historian triggers set to 0 send buffer ready notifications with each trend sample, leading to high CPU load
    • Driver upgrade/downgrade may result in download errors that require downloading again
    • Point count exceeded messages may be erroneously displayed
    • Disable Service Ports option may not actually disable service ports when checked
    • Network points to devices on BACnet/Ethernet networks that have gone offline never go into error
    • Driver > Connections page not displaying when homed on B/SC
    • External BACnet property writes are not triggering an archive
    • Locked I/O alarm may continue to show after CP with locked point is removed
    • Controller homed on B/SC network treating "this" as BACnet object name instead of wildcard
    • Changing a MODBUS TCP network point URL or refresh time may cause point to show "20 - No connection available" and stop being serviced until restart
    • CPU usage dramatically increases as number of network points increases
    • Disabling/Re-enabling a network point causes it to show Uninitialized until restart
    • BACnet network points that don't initially bind correctly are never retried
    • Who-Has is never sent when using device name in network point
    • When the enable input on a BACnet ANO2 MB changes to True the MB always writes a 0 prior to writing the actual wire value
    • Network points pointing to internal BACnet objects in Airflow MB show Configuration Error
    • Errors are initially shown on BACnet ANOs using object names when points are actually updating correctly
    • Network points using wildcards (e.g. */<objectname>) will not bind to points residing in the same controller
    • Redownloading a controller with a large number of MODBUS points causes the controller to run out of memory


    Enhancements

    • Support for OFRTR-E2-S2
    • ARCNET Controllers Online now shown in S1/S2 Connection tab of Driver page
    • Added option to disable Eth0 and Eth1
    • Security improvements
    • MAC address can now be changed on the home network, via the BAS Driver page
    • Support for Invensys ASD PPD

    Known Issues

    • See Gen5 Firmware Advisory.
    in News
    # Automated Logic
    Gen5 Firmware Advisory - Update 1
      